Ylx Series Oil-Sucking Filter On Oil Tank

Short Description:

The overheater is suitable for dropping impurities in the oil at the oil suction port of the oil pump, so as to protect the oil pump and other hydraulic components, effectively control the pollution of the hydraulic system, and improve the cleanliness of the hydraulic system.

The superheater is equipped with a transmitter, a bypass valve and a pollution collecting cup. The utility model has the advantages of large oil passing capacity and small resistance. It has obtained the utility model patent certificate of the State Patent Office. The main performance characteristics are as follows:


Product Detail

Product Tags

Introduction

The overheater is suitable for dropping impurities in the oil at the oil suction port of the oil pump, so as to protect the oil pump and other hydraulic components, effectively control the pollution of the hydraulic system, and improve the cleanliness of the hydraulic system.

The superheater is equipped with a transmitter, a bypass valve and a pollution collecting cup. The utility model has the advantages of large oil passing capacity and small resistance. It has obtained the utility model patent certificate of the State Patent Office. The main performance characteristics are as follows:

1. The superheater is directly installed on the cover plate of theoil tank, and the cylinder extends into the oil of the oil tank. The oil outlet is provided with two connection modes of thread and flange, which are connected with the oil suction port of the oil pump. The pipeline is simple and easy to install.

YLX SERIES OIL-SUCKING FILTER ON OIL TANK

2. When the leaking core is blocked and needs to be cleaned or replaced, just open the upper cover of the superheater to take out the dripping core for cleaning or replacement, which is very convenient.

3. The oil outlet of the superheater is provided with a leakage core blocking transmitter, which has two functions of visual and automatic transmission. By observing the indicator on the transmitter, we can know the blockage of the leakage core at any time. When the dripping core is blocked and the vacuum degree of oil outlet reaches 0.03mpa, the transmitter will send a signal. At this time, stop the machine to clean or replace the heater core.

4. A bypass valve is set on the upper part of the temperature core. When the alarm of the transmitter fails to deal with the fault immediately, and the vacuum degree of the oil outlet rises to 0.032mpa, the bypass valve will open automatically, and the oil circuit will be opened separately, so as to protect the leaker from damage, avoid the phenomenon of air suction of the oil pump, and ensure the normal operation of the system.

5. During the operation of the system, when the oil flows through the inner chamber of the core, the pollutants exceeding the over temperature accuracy of the core will be blocked in the core and concentrated in the core. When the core is cleaned or replaced, the pollution will be brought out together with the core, so as to prevent the pollutants that have been leaked from falling into the oil tank again when the core is replaced, so as to maintain the cleanliness of the oil.

Model Code

2321
we2

Technical Data

Parameters/ Model Nominal Dia(mm) Nominal Flow(L/min) FiltrationAccuracy(pm) InitialPressure loss Allowed max.Pressure loss By-pass openingpressure Pressure uponSignal-sending Signal sending ConnectionMode FiltrationCore Model
(MPa) (V)

(A)

YLX-25 x ** 15 25 80100180 <0.01 0.03 >0.032 0.03 122436 2.521.5 ThreadedFlanged X-X25 x**
YLX-40 x ** 20 40 X-X40 x **
YLX-63 x ** 25 63 X-X63 x**
YLX-100 x** 32 100 X-X100 x**
YLX-160 x ** 40 160 X-X160 x**
YLX-250 x ** 50 250 X-X250 x **
YLX-400 x ** 65 400 X-X400 x **
YLX-630 x ** 80 630 X-X630 x**
YLX-800 x ** 90 800 X-X800 x**

Note: * for filtration accuracy, if the medium used is water glycol, the flow rate is 250L / min, the filtration accuracy is 80mm, with transmitter, the filter is marked as ylx · bh-250 x 80fc, and the filter element model is x-x - bh250 x 80.

Mounting Size

Mounting Size11
Model DI D2 D3 D4 D5 D6 D7 Hl H2 H3

L

n-d
YLX-25 x * 74 95 no G3/4” 55 M22X1.5 19 160 60 58 100 4-Φ7
YLX-40 x * G3/4” 60 M27X2 22 200
YLX-63 x * 95 115 135 Gl” 70 M33X2 27 62

65

125 4-Φ9
YLX-100 x *

YLX-160 x*

G2 1/4”

G21/2”

80

85

M41X2

M48X2

35

41

250

306

YLX-250 x * 120 150 175 G2” 100 85 53 277 70 74 140
YLX-400 x * 146 175 200 G2 1/2” 116 100 66 340 80 78 150
YLX-630 x * 165 200 220 G3” 130 116 80 380 90 90 160
YLX-800 x * 185 205 225 G4” 140 124 93 435 108 139 6-Φ9